Product Description Uses the Sentinel 3100 measures to a wide variety of materials in a Class 1, Division 2 area.
The rugged, cast housing is epoxy-coated for corrosion resistance. Mounting bosses allow installation to sightglasses or an walls.
The Sentinel 3100 measures to any surface or material, including granular and coarse solids, liquid slurries and pastes.
The accuracy of measurements is not affected by: temperature of material, varying pressure barriers, angle of repose, proces tank obstacles/build-up, varying stratified vapour layers, acoustically absorbing materials, small tank diameters, tall tanks and materials with low dielectric constants. Product Feature
- Eye Safety : Will not harm the naked eye when used in normal operation. See specifications.
- Programmable : Field programmable internal features include : unit of measurement, warning codes, number of readings/sec, Windowing/blanking settins, and analog limits. Programming is via the RS-232 serial port using a computer and any communications program, or Optech's optional handheld remote display/programmer.
- Data Outputs : 4-20 mA and RS422.
- No Calibration Required : The rangefinder is factory calibrated for absolute readings. No further field adjustments are required.
- Automatic Self-Diagnostics : On power-up, the instrument conducts extensive internal diagnostics.
- Automatic Signal Processing : Return signals are analyzed and verified; warning codes report anomalous signals or equipment failure.
- Dynamic Accuracy : Range and accuracy measurements are unaffected by materials that are being agitated. Measurements can be timed to avoid interference from agitator blades.
- Quick Commissioning and Troubleshooting : The visible laser pointer enables precise location of the infrared measuring laser, on the target.
Product Specification/Models
| RANGE 1 |
0.2 m -250 m |
| LASER
CHARACTERISTICS |
Beam divergence |
5 mard(0.28o) |
| Laser spot size |
4 cm + (0.005 x distance in cm) |
| Laser wavelength |
905 nm (IR measuring beam)
635 nm (visible pointer) |
| PERFORMANCE |
Absolute accuracy2 |
Within 2 cm |
| Operating accuracy3 |
Within 5 mm |
| Repeatability4 |
Within 3 mm |
| Resolution |
1 mm |
| OUTPUTS(1000
VDC isolation) |
Measurement rate |
Programmable from 1 reading every 5
sec to 20 readings/sec |
| Units of measurement |
Meters or feet |
| Analog current loop5 |
4-20 mA; max 1200 ohm
Programmable zero/max |
| Digital data |
Serial RS422 |
| LOCAL SETUP/TEXT |
RS232C port |
| POWER (1000
VDC isolation) |
Consumption |
36 W max.@ 24 VDC |
| Input voltage |
24 DVC nominal (10.5-30 VDC) |
| ENCLOSURES
(all CE marked) |
Sentinel 3100 |
nema 4, 4x, 6
IP67
CSA Class 1, Div 2 Group ABCD
CSA Class 2 Group EFG
Exn Zone 2
NRTL/OSHA to UL 1604
Size in mm: 280 L x 205 W x 155 D
Weight: 7kg |
| Sentinel 3200 |
NEMA 4, 7, 9
Class 1 Div 1, Group BCD
Size in mm: 335 L x 305 W x 305 D
Weight: 20kg |
| Sentinel 3300 |
NEMA 4
IP66
Extends operating temp from 50oC to 150oC
Size in mm: 335 L x 255 W x 100 D
Weight: 10 kg |
| ENVIRONMENTAL |
Operating temperature6 |
-40oC to +50oC |
| Storage temperature |
-40oC to +70oC |
| EYE SAFETY |
IR(infrared) laser |
Class 1 (U.S. FDA 21 CFR 1040 and IEC
825.1-1993) |
| Visible pointer |
Class 2 (U.S. FDA 21 CFR1040 and IEC
825.1-1993) |
|